Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob.
4. With a thin screwdriver, adjust the
bypass screw position (A).
5.
If you change:
• from natural gas G20/G25 20/25
mbar to liquid gas, fully tighten the
bypass screw in.
• from liquid gas to natural gas
G20/G25 20/25 mbar, undo the
bypass screw approximately 1/4 of a
turn (1/2 of a turn for Multi Crown
burner).
WARNING! Make sure the
flame does not go out when you
quickly turn the knob from the
maximum position to the
minimum position.
Electrical connection
• Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the
local power supply.
• This appliance is supplied with a mains
cable. It has to be supplied with a
correct plug which can hold the load
that the rating plate rates. Make sure
that you install the plug in a correct
socket.
• Always use a correctly installed
shockproof socket.
• Make sure that there is an access to the
mains plug after the installation.
• Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
• There is a risk of fire when the appliance
is in connection with an extension cable,
an adapter or a multiple connection.
Make sure that the ground connection
agrees with the standards and
regulations.
• Do not let the power cable to heat up to
a temperature higher than 90° C.
Make sure that you connect the
blue neutral cable to the terminal
with a letter "N" on it. Connect
the brown (or black) phase
cable to the terminal which has
a letter "L". Keep the phase
cable connected at all times.
Connection cable
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H03V2V2-FT90.
Make sure that the cable section is
applicable to the voltage and the working
temperature. The yellow / green earth wire
must be approximately 2 cm longer than
the brown (or black) phase wire.
Assembly
1.
13